4920000283597 000283597 MILS7610BASIC 1304-100 930-600

A cabinetlike item usually with a front work area and consisting of the necessary instrumentation, integral hydraulic system and component mounting facilities. Designed to provide the hydraulic pressure for testing and/or calibrating hydraulic system components, such as valves, actuating cylinders, pressure regulators, accumulators, hose lines, hand and/or engine driven pumps and the like. May include facilities for filling and checking hydraulic systems for leakage and performance. See also PUMPING UNIT, HYDRAULIC. View more Hydraulic System Components Test Stand

4920-00-028-3597 TEST STAND,HYDRAULIC SYSTEM COMPONENTS 4920000283597 000283597

Managed by United States
NSN Created on 1 Jan 1961
Data Last Changed
January 2023
NATO Update Count
34
NATO Data Quality
4920-00-028-3597 TEST STAND,HYDRAULIC SYSTEM COMPONENTS 4920000283597 000283597 1/1
NSN 4920-00-028-3597 (Generic Image) 1/1

4920-00-028-3597 Stock and Availability Marketplace 4920-00-028-3597

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
4920-00-028-3597 RQST NE eBay
eBay Updated Every Day
4920-00-028-3597 RQST eBay
Amazon Updated Every Day
4920-00-028-3597 RQST NE Amazon

4920-00-028-3597 Related Documents Related Documents 4920-00-028-3597 4+ Documents (More...)

2990-01-676-2715 2990016762715 016762715 is a heater designed to burn fuel or utilize electric power which applies heat through direct connection to the engine coolant system to facilitate starting in low temperatures; may also supply heated coolant to heat exchangers. must have mounting facilities. see also heater, air duct, engine and heater, air duct-coolant, engine.
for $1 a day Upgrade your Account Upgrade 2530-00-839-5941Brake Lining Kit2530008395941 008395941 1304-100
2990-01-148-5074 2990011485074 011485074 is a heater designed to burn fuel or utilize electric power which applies heat through direct connection to the engine coolant system to facilitate starting in low temperatures; may also supply heated coolant to heat exchangers. must have mounting facilities. see also heater, air duct, engine and heater, air duct-coolant, engine.
-620-5825 Hydraulic System Components Test Stand 51786RNCC: 3 | RNVC: 9 | DAC: 4 31 Jul 2013 4920-00-028-3597

4920-00-028-3597 Demil Restrictions 4920-00-028-3597

DEMIL: B | DEMILI: 3 | CRITICALITY: X | HMIC: N | PMIC: A | EDC: A | ADPEC: 0

4920-00-028-3597 is a Hydraulic System Components Test Stand that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a US Munitions List Item and must be mutilated to scrap. This item is not suspected to be hazardous. This item does not contain a precious metal.

4920-00-028-3597 HTS and ScheduleB Import and Export 4920-00-028-3597

4920-00-028-3597 End Users End Users 4920-00-028-3597

Spain (YB01)
Effective Date:
1 Apr 1991
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Norway (ZT01)
Effective Date:
1 Apr 1991
Greece (ZU01)
Effective Date:
1 Apr 1991
Turkey (ZW01)
Effective Date:
1 Dec 1995

4920-00-028-3597 Manufacturers Approved Sources 4920-00-028-3597

4920-00-028-3597 Technical Data Datasheet 4920-00-028-3597

Characteristic
Specifications
FIIG
T361-E
Accumulator [AYJM]
Not Included
Current Type [ACDC]
Ac
Departure From Cited Document [ZZZW]
Basic Only
Engine Driven Hydraulic Pump Testing Design Feature [CGYK]
Not Included
Filtering System [CHGQ]
Included
Frequency In Hertz [FREQ]
60.0
Horsepower Rating [ANCY]
20.0
Hydraulic Fluid Flow Rate [AAYJ]
10.0 Gallons Per Minute
Hydraulic Fluid Flow Rate [AAYJ]
5.0 Gallons Per Minute
Nondefinitive Spec/Std Data [ZZZT]
D-6 Type
End Item Identification [AGAV]
Multi-Aircraft Systems Age
Functional Classification [FCLS]
Gg-5.3
Functional Description [FTLD]
Designed To Bleed Air,Drain,Flush And Refill The Acft Systems With Micronically Filtered Hydraulic Fluid
Reference Data And Literature [RDAL]
T.O. 33A2-2-23-31
Installation Design [AMQY]
Portable
Power Source [ATJK]
Electric Motor
Pressure Manifold Subcircuit [CGYM]
Not Included
Pressure Rating [BGST]
3000.0 Pounds Per Square Inch Nominal And 5000.0 Pounds Per Square Inch Nominal
Pressure/Suction Hose [CHGR]
Included
Phase [FAAZ]
Three
Special Features [FEAT]
Single System
Usage Design [ALBY]
Aircraft Hydraulic System
Voltage In Volts [ELEC]
220.0 And 440.0

4920-00-028-3597 Related Items NATO Stock Numbers Related to 4920-00-028-3597

4920-00-028-3597 Freight Data Freight Information 4920-00-028-3597

4920-00-028-3597 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 147650. A Sub NMFC of X. It has a NMFC Description of OUTFITS MILITARY EQUIP FOR REPAIR. 4920-00-028-3597 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. 4920-00-028-3597 is rated as class 92.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 73790 which rates the freight between FCL and LCL. It has a Water Commodity Code (WCC) of 72B for ocean manifesting and military sealift. 4920-00-028-3597 is classified as Aircraft Engine, Internal Combustion Engine or Fuel Control Device when transported by water. 4920-00-028-3597 is not a consolidation, but exceeds 84" in at least one dimension. It may not be compatible with a standard 72" Aircraft Cargo Door when transported by air.

4920-00-028-3597 Packaging Data Packaging Data 4920-00-028-3597

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
85.0" H x 67.0" W x 58.0" L
--
--
Over 10lb
Less than 85G
MIL-PRF-16173, Cosmoline, Grade 2, Soft Film

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
Special Requirement
Special Requirements – see Specific Instructions or Drawings provided
Special Requirements. See Specific Instructions or Drawings Provided
Special Requirements. See Specific Instructions or Drawings Provided
Special requirement – See specific instructions or drawings provided
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
No Requirement