Premium Information is available for this item - Upgrade for $1 a day

5445-00-286-5373

Tower

5445002865373 002865373 RADCEXHIBIT2293 AB396AMPS11

An open frame structure which is high in proportion to its lateral dimensions and has more than a single footing or mounting base. It is normally used to support such items as antennas, loudspeakers, water tanks, cabins, and the like, which may be furnished. Excludes TOWER, DOUBLE STRUCTURE, SURVEYING and MAST. View more Tower

5445-00-286-5373 TOWER 5445002865373 002865373

Managed by United States
NSN Created on 28 Jan 1966
Data Last Changed
January 2023
NATO Update Count
6
NATO Data Quality
5445-00-286-5373 TOWER 5445002865373 002865373 1/1
NSN 5445-00-286-5373 (Generic Image) 1/1

5445-00-286-5373 Stock and Availability Marketplace 5445-00-286-5373

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5445-00-286-5373 RQST NE eBay
eBay Updated Every Day
5445-00-286-5373 RQST eBay
Amazon Updated Every Day
5445-00-286-5373 RQST NE Amazon

5445-00-286-5373 Related Documents Related Documents 5445-00-286-5373 4+ Documents (More...)

1968 5985-00-269-3443 Mast Section 63B19286RNCC: 3 | RNVC: 2 | MEDALS: Y | DAC: A 1 Jan 1963 5445-00-286-5373
https//www.nsnlookup.com /cage Rome Air Development Center (CAGE Code 07877) DAC: A 1 Jan 1963 5445-00-286-5373
AssyUOMTechnical DocumentQuantative ExpressionDepartment of the Air Force (DF)LEReplaced By 5445-00-286-5373
RNVC: 2 | DAC: X 1 Jan 1961 5445-00-944-6601 Tower TYPE1RNCC: 3 | RNVC: 2 | DAC: 4 11 Feb 1966 5445-00-286-5373

5445-00-286-5373 Demil Restrictions 5445-00-286-5373

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: A | EDC: | ADPEC: 0

IUID Required

5445-00-286-5373 is a Tower that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.

5445-00-286-5373 HTS and ScheduleB Import and Export 5445-00-286-5373

5445-00-286-5373 End Users End Users 5445-00-286-5373

US Air Force (FGG4)
Effective Date:
8 May 2001
US Air Force (FUU4)
Effective Date:
1 Jun 2014

5445-00-286-5373 Manufacturers Approved Sources 5445-00-286-5373

5445-00-286-5373 Technical Data Datasheet 5445-00-286-5373

Characteristic
Specifications
FIIG
T324-K
Elevating Facility [CCMY]
Snatch Block
Assembly Form [ALPM]
Sectionalized
Bottom Length [CCMH]
3.000 Feet Nominal
Bottom Width [AQTW]
3.000 Feet
Cabin [CCMM]
Not Included
Capacity [AXQD]
2500.0 Pounds
Climbing Facility [CCMK]
Ladder
Grounding Provision [AERK]
Included
Height [HGTH]
28.500 Feet Nominal
Material [MATT]
Steel
Joint Electronics Type Designation System Item Name [AKWA]
Tower
Joint Electronics Type Designation System Item Type Number [AKWB]
Ab396a/Mps-11
Lightning Rod [CCMX]
Not Included
Rest Platform Quantity [CCML]
1
Section Quantity [AAPN]
5
Shape [SHPE]
Square
Supported Item Name [CCMG]
Antenna
Top Width [ARRW]
3.000 Feet Nominal
Top Length [CCMJ]
3.000 Feet Nominal

5445-00-286-5373 Management Data Management Data 5445-00-286-5373

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Jun 2020
Department of the Air Force (DF)
EA
Subscribe
1
Jun 2014
Department of the Air Force (DF)
EA
Subscribe
1
MOE
USC
Code
Statement
Order of Use
Jump To Code
Qty Per Assy
UOM
Technical Document
Quantative Expression
Department of the Air Force (DF)
L
G
Replaces 5445-00-270-4925
AAA
Department of the Air Force (DF)
L
Dod I&S Family Master Nsn - - -
AAB

Air Force Air Force

Budget:
M
57X3080 - Other Base Maintenance and Support Equipment
Aggregation Code:
JT
RIGID WALL SHELTERS
Price Validation Code:
V
The current standard price has been validated.
The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Expendability
Recoverability
Repairability:
U
Reparable. Condemn at Intermediate. AF Equipment Management System (AFEMS).

5445-00-286-5373 Related Items NATO Stock Numbers Related to 5445-00-286-5373

5445-00-286-5373 Freight Data Freight Information 5445-00-286-5373

5445-00-286-5373 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 187010. A Sub NMFC of X. It has a NMFC Description of TOWERS NOI STL/WD SEP/COMB KD. 5445-00-286-5373 is rated as class 55 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 92020 which rates the freight between FCL and LCL. 5445-00-286-5373 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 574 for ocean manifesting and military sealift. 5445-00-286-5373 is classified as a Protected/Sensitive Non-Hazardous Non-ESD Commodity when transported by water. 5445-00-286-5373 is not a consolidation, but exceeds 84" in at least one dimension. It may not be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5445-00-286-5373 Packaging Data Packaging Data 5445-00-286-5373

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
--
--

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
Special Requirement
Special Requirements – see Specific Instructions or Drawings provided
Special Requirements. See Specific Instructions or Drawings Provided
Special Requirements. See Specific Instructions or Drawings Provided
Special requirement – See specific instructions or drawings provided
Special requirements

Intermediate Pack Level

Quantity of Unit Packs
Container
--
No Requirement