Premium Information is available for this item - Upgrade for $1 a day
5905-00-003-2492
Nonprecision Wire Wound Variable Resistor
5905000032492 000032492 905238 55-120-008
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION. View more Nonprecision Wire Wound Variable Resistor
January 2023
8
Marketplace 5905-00-003-2492
Request a Quotation from participating marketplace vendors
Related Documents 5905-00-003-2492 5+ Documents (More...)
Nonprecision Wire Wound Variable Resistor 5905-00-003-2492 5905000032492 000032492 is a resistor
-133 905238-107 Managed by United States NSN Created on 4 Sep 1968 Data Last Changed May 2023 NATO Update
Request a Quotation from participating marketplace vendors Request Subscribe to View Vendor Details... 905238
-131 905238-105 Managed by United States NSN Created on 4 Sep 1968 Data Last Changed May 2023 NATO Update
Request a Quotation from participating marketplace vendors Request Subscribe to View Vendor Details... 905238
Restrictions 5905-00-003-2492
5905-00-003-2492 is a Nonprecision Wire Wound Variable Resistor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5905-00-003-2492
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
Approved Sources 5905-00-003-2492
- Part Number
- Manufacturer
- Status
- 905238
- Manufacturer
- 1PQF4 - Cae Usa Inc. (Active)
- Primary Buy
- Primary Buy
- 55-120-008
- 18065 - Samarius Precision Instruments, Inc. (Active)
- Secondary Buy
- Secondary Buy
- 905238
- 36378 - Raytheon Technical Services Company (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete