Premium Information is available for this item - Upgrade for $1 a day
5925-00-042-7805
Circuit Breaker
5925000427805 000427805 L505001064 2282221-24
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
May 2023
4
Marketplace 5925-00-042-7805
Request a Quotation from participating marketplace vendors
Restrictions 5925-00-042-7805
5925-00-042-7805 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5925-00-042-7805
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-042-7805
- US Navy (N9BN)
- Effective Date:
- 1 Jul 2005
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
Approved Sources 5925-00-042-7805
- Part Number
- Manufacturer
- Status
- L505001064
- Manufacturer
- 36090 - Lockheed Martin Librascope (Active)
- Primary Buy
- Primary Buy
- 2282221-24
- 10001 - Navair And Navsea Managed (Active)
- Vendor Drawing
- Vendor Drawing
Datasheet 5925-00-042-7805
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole One
- Auxiliary Switch Function And Quantity [CPRZ]
- 1 Control
- Body Length [ADAQ]
- 1.622 Inches Nominal
- Body Style [AAQL]
- Single Pole Type
- Body Width [ADAT]
- 0.625 Inches Nominal
- Bushing Length [ABXD]
- 0.380 Inches Nominal
- Case Material [ADTV]
- Metal
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 0.906 Inches Nominal
- Circuit Protection Type [CPRH]
- Overcurrent Single Location
- Frequency In Hertz [FREQ]
- 60.0 Single Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 7.5 Amperes Ac Single Location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 300.0 Ac Single Location
- Mounting Facility Type And Quantity [AXHR]
- 1 Threaded Bushing W/Panel Seal
- Mounting Surface To Terminal End Distance [AJWX]
- 1.656 Inches Nominal
- Nominal Thread Size [CQJX]
- 0.375 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 240.0 Ac Single Location
- Fragility Factor [AFJN]
- Moderately Rugged
- Special Handling Feature [BBRJ]
- Magnetic
- Storage Type [BBRG]
- General Purpose Warehouse
- Inclosure Protection Type For Which Designed [CQXF]
- Hermetically Sealed
- Internal Trip Release Configuration [CPSM]
- Series Trip Single Location
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 1
- Reset Method [CPRQ]
- Manual
- Trip Release Characteristic [CPRL]
- Instantaneous Single Location
- Trip Release Method [CPRJ]
- Magnetic Single Location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 150.0 Single Location
- Ultimate Trip Time Per Pole In Seconds [CPRP]
- 0.005 Nominal Single Location
- Switch Location And Position Designation [CQSM]
- Internal At Pole One
- Switch Terminal Type [CRTK]
- Wire Hook
- Switch Voltage Rating And Type In Volts [CSWP]
- 120.0 Ac And 50.0 Dc
- Switch Contact Arrangement [AEGJ]
- Single Pole, Double Throw
- Switch Current Rating And Type In Amps [CSSX]
- 0.5 Ac And 0.5 Dc
- Terminal Type And Quantity [TTQY]
- 2 Wire Hook
- Thread Quantity Per Inch [CMLP]
- 32
- Thread Series Designator [THSD]
- Unef
DLA Procurement Analysis 5925-00-042-7805
Management Data 5925-00-042-7805
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 5925-00-042-7805
Freight Information 5925-00-042-7805
5925-00-042-7805 has freight characteristics managed by the Food and Drug Administration (FDA).It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-042-7805 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-042-7805 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-042-7805 is not classified as a special type of cargo when transported by water. 5925-00-042-7805 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5925-00-042-7805
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- --
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- --
- --
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- See Method of Preservation
- --
Contracting Technical Data File (CTDF) 5925-00-042-7805 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: