Premium Information is available for this item - Upgrade for $1 a day
5925-00-055-6046
Circuit Breaker
5925000556046 000556046 J74-0028 F3060
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
June 2023
5
Marketplace 5925-00-055-6046
Request a Quotation from participating marketplace vendors
Related Documents 5925-00-055-6046 5+ Documents (More...)
Wahidullah Ahmadzai Ltd Frequently Asked Questions (FAQ) for CAGE F3060 What is CAGE Code F3060?
Sa located at 15 Rue Clavel, Paris 19, 75019, France.Who is CAGE Code F3060?
/fsg-48/fsc-4810/fr
) F3060 Mattey (A.)
Sa is a Cancelled Without Replacement Manufacturer with the Cage Code F3060.
Restrictions 5925-00-055-6046
5925-00-055-6046 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5925-00-055-6046
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-055-6046
- NASA (G900)
- Effective Date:
- 1 Apr 1991
Approved Sources 5925-00-055-6046
- Part Number
- Manufacturer
- Status
- J74-0028
- Manufacturer
- 20019 - Ward Leonard Ct Llc (Active)
- Primary Buy
- Primary Buy
- F3060
- 89946 - Eaton Corporation (Active)
- Secondary Buy
- Secondary Buy
Datasheet 5925-00-055-6046
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole Two
- Body Height [ADAU]
- 3.751 Inches Minimum And 3.875 Inches Maximum
- Body Length [ADAQ]
- 9.313 Inches Minimum And 9.437 Inches Maximum
- Body Style [AAQL]
- Multipole-Single Actuator Type
- Body Width [ADAT]
- 4.063 Inches Minimum And 4.187 Inches Maximum
- Boss Height [AJEC]
- 0.438 Inches Minimum And 0.562 Inches Maximum
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 3.782 Inches Minimum And 3.906 Inches Maximum
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 1.313 Inches Minimum And 1.437 Inches Maximum
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 7.063 Inches Minimum And 7.187 Inches Maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
- 1.313 Inches Minimum And 1.437 Inches Maximum
- Frequency In Hertz [FREQ]
- 60.0 All Locations
- Arc Quenching Method [APNQ]
- Deion
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 100.0 Amperes Ac All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 15000.0 Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 4 Unthreaded Hole
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 208.0 Ac All Locations
- Fragility Factor [AFJN]
- Moderately Rugged
- Special Handling Feature [BBRJ]
- Magnetic
- Storage Type [BBRG]
- General Purpose Warehouse
- Inclosure Protection Type For Which Designed [CQXF]
- General Purpose
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 50.000 Minimum At 200 Pct All Locations And 210.000 Maximum At 200 Pct All Locations
- Trip Release Ambient Temp Rating [CRCF]
- 25.0 Deg Celsius Nominal All Locations
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Thermal-Magnetic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.281 Inches Nominal
- Terminal Type And Quantity [TTQY]
- 6 Compression
NATO Stock Numbers Related to 5925-00-055-6046
Freight Information 5925-00-055-6046
5925-00-055-6046 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-055-6046 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-055-6046 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-055-6046 is not classified as a special type of cargo when transported by water. 5925-00-055-6046 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.