Premium Information is available for this item - Upgrade for $1 a day

5925-00-056-8926

Circuit Breaker

5925000568926 000568926 AP-12-3-61-202 712A202

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-00-056-8926 CIRCUIT BREAKER 5925000568926 000568926

Managed by United States
NSN Created on 1 Jan 1961
Data Last Changed
May 2023
NATO Update Count
6
NATO Data Quality
AAQL Style 1B for 5925-00-056-8926 1/1
NSN 5925-00-056-8926 (Identification) 1/1

5925-00-056-8926 Stock and Availability Marketplace 5925-00-056-8926

Need Help?
Request a Quotation from participating marketplace vendors
FedMallFedMall.mil Updated Every 15 Minutes
5925-00-056-8926 BUY NE FedMallFedMall.mil
eBay Updated Every Day
5925-00-056-8926 RQST NE eBay
eBay Updated Every Day
5925-00-056-8926 RQST eBay
Amazon Updated Every Day
5925-00-056-8926 RQST NE Amazon

5925-00-056-8926 Demil Restrictions 5925-00-056-8926

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC:

5925-00-056-8926 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5925-00-056-8926 HTS and ScheduleB Import and Export 5925-00-056-8926

5925-00-056-8926 End Users End Users 5925-00-056-8926

US Army (A918)
Effective Date:
1 Apr 2006
Former MOE Rule:
A196

5925-00-056-8926 Manufacturers Approved Sources 5925-00-056-8926

5925-00-056-8926 Technical Data Datasheet 5925-00-056-8926

Characteristic
Specifications
FIIG
A030A0
Actuator Function [CPRW]
Trip-Reset
Actuator Position Designation [CPRX]
Between Pole One And Two
Body Length [ADAQ]
1.562 Inches Maximum
Body Style [AAQL]
Multipole-Single Actuator Type
Body Width [ADAT]
1.281 Inches Maximum
Bushing Length [ABXD]
0.380 Inches Maximum
Case Material [ADTV]
Metal
Center To Center Distance Between Terminals Parallel To Length [AEBP]
0.407 Inches Minimum And 0.469 Inches Maximum
Center To Center Distance Between Terminals Parallel To Width [AEBQ]
0.640 Inches Maximum
Center To Center Distance Between Terminals Parallel To Width [AEBQ]
0.610 Inches Minimum And
Circuit Protection Type [CPRH]
Overcurrent All Locations
Frequency In Hertz [FREQ]
50.0 All Locations Or 60.0 All Locations
Arc Quenching Method [APNQ]
Magnetic Blowout
Maximum Continuous Load Current Rating Per Pole [CPLM]
2.0 Amperes Ac All Locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
1000.0 Ac All Locations
Mounting Facility Type And Quantity [AXHR]
1 Threaded Bushing W/Panel Seal
Mounting Surface To Terminal End Distance [AJWX]
1.780 Inches Maximum
Nominal Thread Size [CQJX]
0.375 Inches
Nonturn Device Diameter [AEFS]
0.235 Inches Minimum And 0.265 Inches Maximum
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
240.0 Ac All Locations
Fragility Factor [AFJN]
Moderately Rugged
Nonturn Device Length [AEFQ]
0.130 Inches Nominal
Nonturn Device Location [AEFN]
At 3 Oclock And At 9 Oclock
Nonturn Device Radius [AEFP]
0.610 Inches Minimum And 0.640 Inches Maximum
Special Handling Feature [BBRJ]
Magnetic
Storage Type [BBRG]
General Purpose Warehouse
Inclosure Protection Type For Which Designed [CQXF]
Shockproof And Hermetically Sealed
Inclosure Protection Type For Which Designed [CQXF]
Vibrationproof And
Internal Trip Release Configuration [CPSM]
Shunt Trip All Locations
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
1 Toggle
Pole Quantity [AKPX]
2
Reset Method [CPRQ]
Manual
Trip Release Characteristic [CPRL]
Time Delay All Locations
Trip Release Method [CPRJ]
Magnetic All Locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
115.0 All Locations
Unpackaged Unit Weight [PKWT]
3.600 Ounces
Terminal Type And Quantity [TTQY]
6 Wire Hook
Thread Quantity Per Inch [CMLP]
32
Thread Pitch Diameters [AAJE]
+0.3503/+0.3537 Inches
Thread Series Designator [THSD]
Unef
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
0.700 Maximum At 200 Pct All Locations
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
0.070 Minimum At 200 Pct All Locations And

5925-00-056-8926 Stock, Inventory and Procurement DLA Procurement Analysis 5925-00-056-8926

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5925-00-056-8926 Management Data Management Data 5925-00-056-8926

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Army (DA)
EA
Subscribe
1
Oct 2021
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2020
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2019
Department of the Army (DA)
EA
Subscribe
1

Army Army

Materiel Category and Inventory Manager:
Q
Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity:
2
Stock Fund Secondary Items
Management Inventory Segment:
3
Insurance Items
This code will identify items for which there may be occasional intermittent demands not sufficiently repetitive to warrant classification as regular stock items, but for which prudence requires that nominal quantity be stocked for the reason that the essentiality of the item and the long lead time required to obtain such items by purchase would create an unacceptable situation if no stock were carried.
Weapons System / End Item / Homogeneous Group:
00
DLA/GSA Material
DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements:
X
Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.

5925-00-056-8926 Related Items NATO Stock Numbers Related to 5925-00-056-8926

5925-00-056-8926 Freight Data Freight Information 5925-00-056-8926

5925-00-056-8926 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-056-8926 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-056-8926 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-056-8926 is not classified as a special type of cargo when transported by water. 5925-00-056-8926 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5925-00-056-8926 Packaging Data Packaging Data 5925-00-056-8926

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
MIL-P-130, Laminated and Creped Wrapping Paper
A-A-1898, Grade II, Water Resistant Cellulosic Cushioning
--
PPP-B-566 or PPP-B-676, Folding or Setup Box
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5925-00-056-8926 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5925-00-056-8926 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: