Premium Information is available for this item - Upgrade for $1 a day

5925-00-066-6896

Circuit Breaker

5925000666896 000666896 A2028633

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-00-066-6896 CIRCUIT BREAKER 5925000666896 000666896

Managed by United States
NSN Created on 1 Jan 1961
Data Last Changed
November 2023
NATO Update Count
7
NATO Data Quality
5925-00-066-6896 CIRCUIT BREAKER 5925000666896 000666896 1/1
NSN 5925-00-066-6896 (Generic Image) 1/1

5925-00-066-6896 Stock and Availability Marketplace 5925-00-066-6896

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5925-00-066-6896 RQST NE eBay
eBay Updated Every Day
5925-00-066-6896 RQST eBay
Amazon Updated Every Day
5925-00-066-6896 RQST NE Amazon

5925-00-066-6896 Related Documents Related Documents 5925-00-066-6896 2+ Documents (More...)

1963 5310-21-817-0492 Spring Tension Washer 2207103G1RNCC: 3 | RNVC: 2 | DAC: 5 19 Apr 1967 5925-00-066-6896
: X 1 Jan 1963 5985-00-727-4373 Mast Section SMC655484RNCC: 5 | RNVC: 2 | DAC: 5 28 Feb 1968 5925-00-066-6896

5925-00-066-6896 Demil Restrictions 5925-00-066-6896

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5925-00-066-6896 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5925-00-066-6896 End Users End Users 5925-00-066-6896

NASA (G900)
Effective Date:
1 Apr 1991

5925-00-066-6896 Manufacturers Approved Sources 5925-00-066-6896

5925-00-066-6896 Technical Data Datasheet 5925-00-066-6896

Characteristic
Specifications
Arc Quenching Method [APNQ]
Magnetic Blowout
Case Material [ADTV]
Plastic
Circuit Protection Type [CPRH]
Overcurrent Single Location
Frequency In Hertz [FREQ]
60.0 Single Location
Maximum Continuous Load Current Rating Per Pole [CPLM]
6.0 Amperes Ac Single Location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
2000.0 Ac Single Location
Mounting Facility Type And Quantity [AXHR]
2 Threaded Hole
Nominal Thread Size [CQJX]
0.138 Inches
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
125.0 Ac Single Location
Inclosure Protection Type For Which Designed [CQXF]
Dustproof
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
1 Toggle
Pole Quantity [AKPX]
1
Reset Method [CPRQ]
Manual
Overall Height [ABKW]
3.170 Inches Nominal
Overall Length [ABHP]
2.500 Inches Nominal
Overall Width [ABMK]
0.750 Inches Nominal
Special Features [FEAT]
Mtg Holes On 2 1/16 In. Centers
Thread Quantity Per Inch [CMLP]
32
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
7.000 Minimum At 150 Pct Single Location And 25.000 Maximum At 150 Pct Single Location And 3.000 Minimum At 200 Pct Single Location And 9.000 Maximum At 200 Pct Single Location And 1.200 Minimum At 300 Pct Single Location And 3.500 Maximum At 300 Pct Single Location And 0.300 Minimum At 500 Pct Single Location And 1.000 Maximum At 500 Pct Single Location And 0.010 Minimum At 1000 Pct Single Location And 0.040 Maximum At 1000 Pct Single Location
Trip Release Characteristic [CPRL]
Instantaneous Single Location And Time Delay Single Location
Trip Release Duty Cycle [CQQC]
Continuous Single Location
Trip Release Method [CPRJ]
Magnetic Single Location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
125.0 Single Location
Terminal Type And Quantity [TTQY]
2 Threaded Stud

5925-00-066-6896 Related Items NATO Stock Numbers Related to 5925-00-066-6896

5925-00-066-6896 Freight Data Freight Information 5925-00-066-6896

5925-00-066-6896 has freight characteristics.. 5925-00-066-6896 has a variance between NMFC and UFC when transported by rail and the description should be consulted.