Premium Information is available for this item - Upgrade for $1 a day
5925-00-071-7543
Circuit Breaker
5925000717543 000717543 900486-509 SM333-5-240VAC400C1
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
May 2023
17
Marketplace 5925-00-071-7543
Request a Quotation from participating marketplace vendors
Restrictions 5925-00-071-7543
5925-00-071-7543 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5925-00-071-7543
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-071-7543
- France (ZF01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5925-00-071-7543
- Part Number
- Manufacturer
- Status
- SM333-5-240VAC400C1
- Manufacturer
- 74193 - Eaton Corp (Obsolete)
- Original Design
- Original Design
- 900486-509
- 06481 - Northrop Grumman Systems Corporation (Active)
- Vendor Drawing
- Vendor Drawing
Datasheet 5925-00-071-7543
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole Two
- Arc Quenching Method [APNQ]
- Magnetic Blowout
- Body Length [ADAQ]
- 1.500 Inches Maximum
- Body Style [AAQL]
- Multipole-Single Actuator Type
- Body Width [ADAT]
- 1.875 Inches Maximum
- Bushing Length [ABXD]
- 0.375 Inches Nominal
- Case Material [ADTV]
- Metal
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 0.875 Inches Nominal
- Center To Center Distance Between Terminals Parallel To Width [AEBQ]
- 0.625 Inches Nominal
- Circuit Protection Type [CPRH]
- Overcurrent All Locations
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 400.0 All Locations
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 5.0 Amperes Ac All Locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 300.0 Ac All Locations
- Mounting Facility Type And Quantity [AXHR]
- 1 Threaded Bushing W/Panel Seal
- Mounting Surface To Terminal End Distance [AJWX]
- 1.780 Inches Maximum
- Nominal Thread Size [CQJX]
- 0.375 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 240.0 Ac All Locations
- Inclosure Protection Type For Which Designed [CQXF]
- Hermetically Sealed
- Internal Trip Release Configuration [CPSM]
- Series Trip All Locations
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 3
- Reset Method [CPRQ]
- Manual
- Special Handling Feature [BBRJ]
- Magnetic
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 3.000 Minimum At 150 Pct All Locations And 14.000 Maximum At 150 Pct All Locations And 1.000 Minimum At 200 Pct All Locations And 4.500 Maximum At 200 Pct All Locations And 0.200 Minimum At 300 Pct All Locations And 1.000 Maximum At 300 Pct All Locations
- Trip Release Characteristic [CPRL]
- Time Delay All Locations
- Trip Release Method [CPRJ]
- Magnetic All Locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 125.0 All Locations
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 6 Wire Hook
- Thread Quantity Per Inch [CMLP]
- 32
- Thread Series Designator [THSD]
- Unef
NATO Stock Numbers Related to 5925-00-071-7543
Freight Information 5925-00-071-7543
5925-00-071-7543 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-071-7543 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. 5925-00-071-7543 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-071-7543 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-071-7543 is not classified as a special type of cargo when transported by water. 5925-00-071-7543 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.