Premium Information is available for this item - Upgrade for $1 a day
5925-00-081-4575
Circuit Breaker
5925000814575 000814575 9978608 AM17-20AMP120VACTDC55 AM17-20-120VAC400-55
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker
January 2023
24
Marketplace 5925-00-081-4575
Request a Quotation from participating marketplace vendors
Related Documents 5925-00-081-4575 1+ Documents (More...)
Restrictions 5925-00-081-4575
5925-00-081-4575 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5925-00-081-4575
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5925-00-081-4575
- Spain (YB01)
- Effective Date:
- 1 Sep 2008
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 2005
Approved Sources 5925-00-081-4575
- Part Number
- Manufacturer
- Status
- AM17-20AMP120VACTDC55
- Manufacturer
- 74193 - Eaton Corp (Obsolete)
- Original Design
- Original Design
- 9978608
- 18876 - Us Army Aviation And Missile Command (Active)
- Secondary Buy
- Secondary Buy
- AM17-20-120VAC400-55
- 74193 - Eaton Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5925-00-081-4575
- Characteristic
- Specifications
- FIIG
- Specifications
- A030A0
- Actuator Function [CPRW]
- Trip-Reset
- Actuator Position Designation [CPRX]
- At Pole One
- Arc Quenching Method [APNQ]
- Magnetic Blowout
- Body Length [ADAQ]
- 2.500 Inches Nominal
- Body Style [AAQL]
- Single Pole Type
- Body Width [ADAT]
- 0.750 Inches Nominal
- Case Material [ADTV]
- Plastic
- Center To Center Distance Between Terminals Parallel To Length [AEBP]
- 1.190 Inches Nominal
- Circuit Protection Type [CPRH]
- Overcurrent Single Location
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
- 1.812 Inches Nominal
- Fragility Factor [AFJN]
- Moderately Rugged
- Frequency In Hertz [FREQ]
- 400.0 Single Location
- Maximum Continuous Load Current Rating Per Pole [CPLM]
- 20.0 Amperes Ac Single Location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
- 3500.0 Ac Single Location
- Mounting Facility Type And Quantity [AXHR]
- 2 Threaded Hole
- Mounting Surface To Terminal End Distance [AJWX]
- 2.000 Inches Nominal
- Nominal Thread Size [CQJX]
- 0.138 Inches
- Operating Voltage Type And Rating Per Pole In Volts [CPRF]
- 120.0 Ac Single Location
- Inclosure Protection Type For Which Designed [CQXF]
- Fungus Resistant And Moisture Resistant
- Internal Trip Release Configuration [CPSM]
- Series Trip Single Location
- Main Contact Tripping Mechanism Type [CPRR]
- Trip Free
- Manual Actuator Type And Quantity [CPRT]
- 1 Toggle
- Pole Quantity [AKPX]
- 1
- Reset Method [CPRQ]
- Manual
- Special Handling Feature [BBRJ]
- Magnetic
- Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
- 2.300 Minimum At 200 Pct Single Location And 9.500 Maximum At 200 Pct Single Location
- Trip Release Characteristic [CPRL]
- Time Delay Single Location
- Trip Release Method [CPRJ]
- Magnetic-Hydraulic Single Location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
- 150.0 Single Location
- Storage Type [BBRG]
- General Purpose Warehouse
- Terminal Type And Quantity [TTQY]
- 2 Screw
- Thread Quantity Per Inch [CMLP]
- 32
- Thread Series Designator [THSD]
- Unc
NATO Stock Numbers Related to 5925-00-081-4575
Freight Information 5925-00-081-4575
5925-00-081-4575 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-081-4575 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-081-4575 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-081-4575 is not classified as a special type of cargo when transported by water. 5925-00-081-4575 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.