Premium Information is available for this item - Upgrade for $1 a day

5925-00-391-0914

Circuit Breaker

5925003910914 003910914 ETN1005 1244C52G05 2903283-5

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER. View more Circuit Breaker

5925-00-391-0914 CIRCUIT BREAKER 5925003910914 003910914

Managed by United States
NSN Created on 28 Mar 1974
Data Last Changed
January 2023
NATO Update Count
23
NATO Data Quality
AAQL Style 15B for 5925-00-391-0914 1/1
NSN 5925-00-391-0914 (Identification) 1/1

5925-00-391-0914 Stock and Availability Marketplace 5925-00-391-0914

5925-00-391-0914 Related Documents Related Documents 5925-00-391-0914 3+ Documents (More...)

5925-01-225-1962 5925012251962 012251962 is a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
1 Jan 1963 5950-00-111-1954 Electrical Coil 505C806G03RNCC: 5 | RNVC: 2 | DAC: 5 14 Aug 1968 5925-00-391-0914

5925-00-391-0914 Demil Restrictions 5925-00-391-0914

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

5925-00-391-0914 is a Circuit Breaker that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

5925-00-391-0914 HTS and ScheduleB Import and Export 5925-00-391-0914

5925-00-391-0914 End Users End Users 5925-00-391-0914

US Coast Guard (C911)
Effective Date:
1 Apr 2006
Former MOE Rule:
C007
US Marine Corps (MC49)
Effective Date:
1 Apr 2006
Former MOE Rule:
MC13
US Navy (N9BN)
Effective Date:
1 Apr 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
GTHDHSJBKE
Brazil (YA01)
Effective Date:
1 Dec 1999
Spain (YB01)
Effective Date:
1 Apr 1991
Malaysia (YW01)
Effective Date:
1 Aug 2007
Australia (ZA01)
Effective Date:
19 Jul 1995
Canada (ZC01)
Effective Date:
1 Apr 1991
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Greece (ZU01)
Effective Date:
1 Jul 2005
Turkey (ZW01)
Effective Date:
1 Nov 1998

5925-00-391-0914 Manufacturers Approved Sources 5925-00-391-0914

5925-00-391-0914 Technical Data Datasheet 5925-00-391-0914

Characteristic
Specifications
FIIG
A030A0
Actuator Function [CPRW]
Trip-Reset
Actuator Position Designation [CPRX]
At Pole Two
Arc Quenching Method [APNQ]
Air
Body Height [ADAU]
3.375 Inches Nominal
Body Length [ADAQ]
4.125 Inches Nominal
Body Style [AAQL]
Multipole-Single Actuator Type
Body Width [ADAT]
3.344 Inches Nominal
Boss Height [AJEC]
0.125 Inches Nominal
Case Material [ADTV]
Plastic
Center To Center Distance Between Terminals Parallel To Length [AEBP]
2.625 Inches Nominal
Center To Center Distance Between Terminals Parallel To Width [AEBQ]
1.125 Inches Nominal
Circuit Protection Type [CPRH]
Overcurrent All Locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length [AEBY]
0.625 Inches Nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width [AEHA]
2.938 Inches Nominal
Fragility Factor [AFJN]
Moderately Rugged
Frequency In Hertz [FREQ]
60.0 All Locations
Maximum Continuous Load Current Rating Per Pole [CPLM]
30.0 Amperes Ac All Locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps [CPRG]
5000.0 Ac All Locations And 2500.0 Dc All Locations
Mounting Facility Type And Quantity [AXHR]
2 Unthreaded Hole
Operating Voltage Type And Rating Per Pole In Volts [CPRF]
500.0 Ac All Locations And 250.0 Dc All Locations
Inclosure Protection Type For Which Designed [CQXF]
Shock Resistant And Vibration Resistant
Internal Trip Release Configuration [CPSM]
Series Trip All Locations
Main Contact Tripping Mechanism Type [CPRR]
Trip Free
Manual Actuator Type And Quantity [CPRT]
1 Toggle
Pole Quantity [AKPX]
3
Reset Method [CPRQ]
Manual
Special Features [FEAT]
Circuit Breaker Supplied With Two 12-24 Mounting Screws 4.125 In. Lg
Special Handling Feature [BBRJ]
Magnetic
Trip Delay Time In Seconds Per Rated Continuous Current [CQWN]
10.000 Minimum At 200 Pct All Locations And 200.000 Maximum At 200 Pct All Locations
Trip Release Ambient Temp Rating [CRCF]
50.0 Deg Celsius Nominal All Locations
Trip Release Characteristic [CPRL]
Instantaneous All Locations And Time Delay All Locations
Trip Release Method [CPRJ]
Thermal All Locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent [CPRN]
138.0 All Locations
Unthreaded Mounting Hole Diameter [AEBV]
0.216 Inches Nominal
Storage Type [BBRG]
General Purpose Warehouse
Terminal Type And Quantity [TTQY]
6 Quick Disconnect, Female

5925-00-391-0914 Stock, Inventory and Procurement DLA Procurement Analysis 5925-00-391-0914

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5925-00-391-0914 Management Data Management Data 5925-00-391-0914

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Jun 2015
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2014
Department of the Navy (DN)
EA
Subscribe
MOE
USC
Code
Statement
Order of Use
Jump To Code
Qty Per Assy
UOM
Technical Document
Quantative Expression
Department of the Navy (DN)
N
F
When Exhausted Use 5925-01-225-1962

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5925-00-391-0914 Related Items NATO Stock Numbers Related to 5925-00-391-0914

5925-00-391-0914 Freight Data Freight Information 5925-00-391-0914

5925-00-391-0914 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 5925-00-391-0914 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 5925-00-391-0914 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 5925-00-391-0914 is not classified as a special type of cargo when transported by water. 5925-00-391-0914 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5925-00-391-0914 Packaging Data Packaging Data 5925-00-391-0914

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
7.0" H x 5.0" W x 5.0" L
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
MIL-PRF-121, Greaseproof, Waterproof Barrier
No Requirement
Not Applicable
PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

5925-00-391-0914 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5925-00-391-0914 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: