Premium Information is available for this item - Upgrade for $1 a day
5945-00-226-0131
Meter Movement Relay
5945002260131 002260131 2097302 30-3622-4509
A relay which operates by means of a D'Arsonval or similar meter type actuation. View more Meter Movement Relay
January 2023
14
Marketplace 5945-00-226-0131
Request a Quotation from participating marketplace vendors
Related Documents 5945-00-226-0131 5+ Documents (More...)
Meter Movement Relay 5945002260131 002260131 www.nsnlookup.com /fsg-59/fsc-5945/us 5945-00-106-
231-2643 5945-37-525-3215 5945-37-525-3216 5945-37-525-3210 5945-00-735-1838 5945-14-324-3008 5945-00-226-0131
Meter Movement Relay 5945002260131 002260131 8948 Meter Movement Relay 5945001068948 001068948
231-2643 5945-37-525-3215 5945-37-525-3216 5945-37-525-3210 5945-00-735-1838 5945-14-324-3008 5945-00-226-0131
Meter Movement Relay 5945002260131 002260131 5945/us 5945-00-106-8948 Meter Movement Relay 5945001068948
231-2643 5945-37-525-3215 5945-37-525-3216 5945-37-525-3210 5945-00-735-1838 5945-14-324-3008 5945-00-226-0131
3068 Meter Movement Relay 5945991423068 991423068 525-3210 5945-00-735-1838 5945-14-324-3008 5945-00-226-0131
3975 Meter Movement Relay 5945991073975 991073975 525-3210 5945-00-735-1838 5945-14-324-3008 5945-00-226-0131
5945/uk 5945-99-954-0422 Meter Movement Relay 5945999540422 999540422 735-1838 5945-14-324-3008 5945-00-226-0131
231-2643 5945-37-525-3215 5945-37-525-3216 5945-37-525-3210 5945-00-735-1838 5945-14-324-3008 5945-00-226-0131
Restrictions 5945-00-226-0131
5945-00-226-0131 is a Meter Movement Relay that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5945-00-226-0131
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5945-00-226-0131
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5945-00-226-0131
- Part Number
- Manufacturer
- Status
- 2097302
- Manufacturer
- 28527 - L3harris Technologies, Inc. (Active)
- Primary Buy
- Primary Buy
- 30-3622-4509
- 80145 - Lfe Instruments (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5945-00-226-0131
- Characteristic
- Specifications
- FIIG
- Specifications
- T142-K
- Case Material [ADTV]
- Plastic
- Contact Closing Condition [APMT]
- Increase Value
- End Item Identification [AGAV]
- Type No. Rtc-2
- Meter Body Diameter [APTF]
- 2.750 Inches Nominal
- Meter Depth Behind Mounting Flange [APST]
- 2.015 Inches Nominal
- Meter Mounting Type [APMR]
- Flush
- Meter Movement Current Range [APGR]
- +0.0/+100.0 Microamperes
- Meter Movement Current Type [APGN]
- Dc
- Meter Movement Voltage In Volts [APGP]
- 0.100 Nominal
- Mounting Configuration [ALGC]
- Four 0.112 In. Dia Mtg Holes On 2.250 In. Mtg Centers
- Mounting Flange Diameter [APTE]
- 3.000 Inches Nominal
- Lock In Device Type [APNS]
- Coil
- Main Contact Arrangement [APDZ]
- 1 Pole, Single Throw, Normally Open, Momentary Action
- Main Contact Current Rating [APEC]
- 0.006 Amperes Nominal
- Main Contact Current Type [APEB]
- Dc
- Release Method [APNT]
- Deenergize Lock-In Coil
- Reset Facility Feature [APNR]
- Provided
- Scale Measurement Range [ANSZ]
- -2.5/+2.5
- Special Features [FEAT]
- 135 Cps Error --Fs Equals 100 Uadc Marked On Meter Face
- Voltage Rating [AMSE]
- 60.0 Volts Nominal
- Terminal Quantity [AARA]
- 5
- Terminal Type [AARB]
- Threaded Stud