Premium Information is available for this item - Upgrade for $1 a day

6145-00-023-6606

Electrical Wire

6145000236606 000236606 NEMA-HP3 C100230444 TE1XAWG30/7/E-CU.VS-4 C1 5Y(E)AWG30/7YE 2851-5 HP3-EXBBB4 HP3-EX-BBB4 HMS271-30AWG-YEL MIL-W-16878/4 M16878/4BBB4

A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. Refers to bulk quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE. View more Electrical Wire

6145-00-023-6606 WIRE,ELECTRICAL 6145000236606 000236606

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
November 2023
NATO Update Count
22
NATO Data Quality
AAGR Style 6 for 6145-00-023-6606 1/1
NSN 6145-00-023-6606 (Identification) 1/1

6145-00-023-6606 Stock and Availability Marketplace 6145-00-023-6606

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
6145-00-023-6606 RQST NE eBay
eBay Updated Every Day
6145-00-023-6606 RQST eBay
Amazon Updated Every Day
6145-00-023-6606 RQST NE Amazon

6145-00-023-6606 Related Documents Related Documents 6145-00-023-6606 5+ Documents (More...)

WIRE -16878 Request MIL-W - MIL-W-16878/4 WIRE - MIL-W-16878/4 WIRE MIL-W- NEMA-HP3 WIRE -16878 MIL-W
MIL-W- NEMA-HP3 WIRE -16878 MIL-W- NEMA-HP3 WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878/4
WIRE MIL-W- NEMA-HP3 - MIL-W-16878/4 WIRE MIL-W WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878
WIRE -16878 Request MIL-W - MIL-W-16878/4 WIRE - MIL-W-16878/4 WIRE MIL-W- NEMA-HP3 WIRE -16878 MIL-W
MIL-W- NEMA-HP3 WIRE -16878 MIL-W- NEMA-HP3 WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878/4
WIRE MIL-W- NEMA-HP3 - MIL-W-16878/4 WIRE MIL-W WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878
WIRE -16878 Request MIL-W - MIL-W-16878/4 WIRE - MIL-W-16878/4 WIRE MIL-W- NEMA-HP3 WIRE -16878 MIL-W
MIL-W- NEMA-HP3 WIRE -16878 MIL-W- NEMA-HP3 WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878/4
WIRE MIL-W- NEMA-HP3 - MIL-W-16878/4 WIRE MIL-W WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878
WIRE -16878 Request MIL-W - MIL-W-16878/4 WIRE - MIL-W-16878/4 WIRE MIL-W- NEMA-HP3 WIRE -16878 MIL-W
MIL-W- NEMA-HP3 WIRE -16878 MIL-W- NEMA-HP3 WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878/4
WIRE MIL-W- NEMA-HP3 - MIL-W-16878/4 WIRE MIL-W WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878
WIRE -16878 Request MIL-W - MIL-W-16878/4 WIRE - MIL-W-16878/4 WIRE MIL-W- NEMA-HP3 WIRE -16878 MIL-W
MIL-W- NEMA-HP3 WIRE -16878 MIL-W- NEMA-HP3 WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878/4
WIRE MIL-W- NEMA-HP3 - MIL-W-16878/4 WIRE MIL-W WIRE -16878 Request MIL-W - MIL-W-16878 - MIL-W-16878

6145-00-023-6606 Demil Restrictions 6145-00-023-6606

DEMIL: A | DEMILI: 1 | CRITICALITY: Y | HMIC: N | PMIC: S | EDC: | ADPEC:

6145-00-023-6606 is a Electrical Wire that does not have a nuclear hardened feature, but does have another critical feature or features such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item contains Silver.

6145-00-023-6606 HTS and ScheduleB Import and Export 6145-00-023-6606

6145-00-023-6606 End Users End Users 6145-00-023-6606

US Air Force (FXGX)
Effective Date:
1 Nov 2005
Former MOE Rule:
FXTX
NASA (G880)
Effective Date:
1 Apr 1991
US Navy (N9BN)
Effective Date:
1 Dec 2013
Supplementary Collaborators:
GGGT
Singapore (YJ01)
Effective Date:
1 Apr 1991
Australia (ZA01)
Effective Date:
1 Apr 1991
Germany (ZG01)
Effective Date:
1 Apr 1991

6145-00-023-6606 Manufacturers Approved Sources 6145-00-023-6606

6145-00-023-6606 Technical Data Datasheet 6145-00-023-6606

Characteristic
Specifications
FIIG
A077A0
Conductor Form [CXCW]
Stranded Single Conductor
Material [MATT]
Copper Core Conductor Single Conductor
Material [MATT]
Plastic Polytetrafluoroethylene 1St Position Primary Insulation Single Conductor
Material Document And Classification [MDCL]
Astm B298 Assn Std Single Material Response Core Conductor Single Conductor
Surface Treatment [SFTT]
Silver Core Conductor Single Conductor
Surface Treatment Document And Classification [STDC]
Astm B298 Assn Std Single Treatment Response Core Conductor Single Conductor
Round Conductor Size [CXDC]
30 Awg Single Conductor
Strand Quantity Per Conductor [BLNZ]
7 Single Conductor
Strand Awg Size Per Conductor [CXDG]
38 Single Conductor
Color [HUES]
Yellow Core Conductor Single Conductor
Voltage Rating [CXFK]
600.0 Maximum Root Mean Square (Rms) Operating Voltage Single Conductor
Cross-Sectional Shape Style [AAGR]
Round
Cross Section Outside Diameter [ADVL]
0.032 Inches Nominal
Temp Rating [ABJH]
200.0 Deg Celsius
Special Features [FEAT]
Weapon System Essential
Criticality Code Justification [CRTL]
Feat
Precious Material [PRMT]
Silver
Precious Material And Location [PMLC]
Surface Single Conductor Silver
End Item Identification [AGAV]
Aircraft, Stratolifter C-135

6145-00-023-6606 Weapon Systems (WSDC) Weapon Systems (WSDC) 6145-00-023-6606

6145-00-023-6606 Stock, Inventory and Procurement DLA Procurement Analysis 6145-00-023-6606

Last Stock Position:
7795 In Stock
DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

6145-00-023-6606 Management Data Management Data 6145-00-023-6606

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Air Force (DF)
FT
Subscribe
Oct 2021
Department of the Air Force (DF)
FT
Subscribe
Dec 2020
Department of the Air Force (DF)
FT
Subscribe
Apr 2020
Department of the Air Force (DF)
FT
Subscribe

Air Force Air Force

Fund:
SF
Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
Budget:
9
57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
Aggregation Code:
EH
ELECTRONIC COMPONENTS
Price Validation Code:
V
The current standard price has been validated.
The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Expendability
Recoverability
Repairability:
N
Expendable. Condemn at User. Stock Fund (except Munitions).

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

6145-00-023-6606 Related Items NATO Stock Numbers Related to 6145-00-023-6606

6145-00-023-6606 Freight Data Freight Information 6145-00-023-6606

6145-00-023-6606 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 030310. A Sub NMFC of Z. It has a NMFC Description of CABLE OR WIRE. 6145-00-023-6606 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 15080 which rates the freight between FCL and LCL. 6145-00-023-6606 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 743 for ocean manifesting and military sealift. 6145-00-023-6606 is not classified as a special type of cargo when transported by water. 6145-00-023-6606 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

6145-00-023-6606 Packaging Data Packaging Data 6145-00-023-6606

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
Plated/Coated Item
2lb or less, one dimension 2" or less, other dimensions less than 24"
Above 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
--
--
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
--
--
--
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
--
No Requirement

6145-00-023-6606 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 6145-00-023-6606 October 2021

Criticality and Quality

Critical Item Code:
X
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
F

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: