6515-00-307-5495

Intravenous Catheter And Needle Unit

6515003075495 003075495 4428

An item consisting of a cannulated needle with an intravenous catheter, and it may contain additional components, such as a hypodermic syringe, needle guard, flow control plug, and the like. The catheter is inserted into the vein by way of the needle's puncture, and is left in position for continued intravenous administration after the needle is withdrawn. A syringe, when supplied, is used to better control insertion of the catheter needle unit or for blood aspiration. View more Intravenous Catheter And Needle Unit

6515-00-307-5495 CATHETER AND NEEDLE UNIT,INTRAVENOUS 6515003075495 003075495

Managed by United States
NSN Created on 19 Oct 1973
Data Last Changed
January 2023
NATO Update Count
7
NATO Data Quality
STYL Style D12 for 6515-00-307-5495 1/1
NSN 6515-00-307-5495 (Identification) 1/1

6515-00-307-5495 Stock and Availability Marketplace 6515-00-307-5495

6515-00-307-5495 Related Documents Related Documents 6515-00-307-5495 5+ Documents (More...)

14 Jul 1995 6515-21-896-0953 Gaseous O Cartridge 2055RNCC: 3 | RNVC: 2 | DAC: 4 29 Apr 1984 6515-00-307-5495
6145-01-312-2236 6145013122236 013122236 is a single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. it may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to bulk quantities only. for items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see wire,(as modified), includes litz wire and insulated/uninsulated armored, and ground wire. excludes braid, wire; fuse wire; resistance wire and magnet wire.
6145-01-312-2235 6145013122235 013122235 is a single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. it may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to bulk quantities only. for items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see wire,(as modified), includes litz wire and insulated/uninsulated armored, and ground wire. excludes braid, wire; fuse wire; resistance wire and magnet wire.
6145-01-312-2234 6145013122234 013122234 is a single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. it may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to bulk quantities only. for items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see wire,(as modified), includes litz wire and insulated/uninsulated armored, and ground wire. excludes braid, wire; fuse wire; resistance wire and magnet wire.
6145-01-312-2239 6145013122239 013122239 is a single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. it may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to bulk quantities only. for items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see wire,(as modified), includes litz wire and insulated/uninsulated armored, and ground wire. excludes braid, wire; fuse wire; resistance wire and magnet wire.

6515-00-307-5495 Demil Restrictions 6515-00-307-5495

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: N | PMIC: A | EDC: | ADPEC:

6515-00-307-5495 is a Intravenous Catheter And Needle Unit that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.

6515-00-307-5495 HTS and ScheduleB Import and Export 6515-00-307-5495

6515-00-307-5495 End Users End Users 6515-00-307-5495

MOE Rule:
V540
Effective Date:
1 Apr 1991

6515-00-307-5495 Manufacturers Approved Sources 6515-00-307-5495

6515-00-307-5495 Technical Data Datasheet 6515-00-307-5495

Characteristic
Specifications
FIIG
A22100
Catheter Nominal Length [ANHQ]
2.500 Inches
Connector Type [ANFJ]
Luer Lock Hub
Core Fabrication Method [ANFS]
Not Woven
Design Designation [ANEH]
Intravenous
Features Provided [CBBL]
Sterile And Disposable
Nominal Diameter [ANHF]
14.000 Gage
Material And Location [ANNQ]
Steel, Corrosion Resisting Needle And Plastic, Polytetrafluoroethylene Catheter
Special Features [FEAT]
Color-Coded; Non-Coring Needle W/Self-Venting Chamber; Unit Qty 200
Style Designator [STYL]
Intravenous Catheter And Needle Unit
Tip Type [ANFG]
Open End

6515-00-307-5495 Related Items NATO Stock Numbers Related to 6515-00-307-5495

6515-00-307-5495 Freight Data Freight Information 6515-00-307-5495

6515-00-307-5495 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 056680. A Sub NMFC of X. It has a NMFC Description of DENTAL/MEDICAL/SURG INST R MACHINE. 6515-00-307-5495 is rated as class 150 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 32570 which rates the freight between FCL and LCL. 6515-00-307-5495 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 651 for ocean manifesting and military sealift. 6515-00-307-5495 is not classified as a special type of cargo when transported by water. 6515-00-307-5495 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.