Premium Information is available for this item - Upgrade for $1 a day
6530-01-539-2252
Central Venous Catheter Tray
6530015392252 015392252 AK-12702-CDC CS-22702-E
An open structure designed to provide all the necessary components required for venous pressure monitoring, blood sampling and administration of drugs and fluids. May include gage needles, lidocaine, prep sponges, fenestrated drape, gauze sponges, slide clamps, triple lumen catheter, clear extension tubes and other related items. Excludes TRAY, CATHETER. View more Central Venous Catheter Tray
January 2023
4
Marketplace 6530-01-539-2252
Request a Quotation from participating marketplace vendors
Related Documents 6530-01-539-2252 5+ Documents (More...)
Central Venous Catheter Tray 6530015392252 539-2250 6530-01-680-9460 6530-01-520-9728 6530-01-539
Central Venous Catheter Tray 6530015392252 520-9734 6530-01-590-7430 6530-01-702-2905 6530-01-517
Central Venous Catheter Tray 6530015392252 539-2250 6530-01-680-9460 www.nsnlookup.com /fsg-65/
Restrictions 6530-01-539-2252
6530-01-539-2252 is a Central Venous Catheter Tray that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6530-01-539-2252
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6530-01-539-2252
- Turkey (ZW01)
- Effective Date:
- 1 Apr 2006
Approved Sources 6530-01-539-2252
- Part Number
- Manufacturer
- Status
- CS-22702-E
- Manufacturer
- 60791 - Arrow International, Inc. (Active)
- Original Design
- Original Design
- AK-12702-CDC
- 8BXN8 - Teleflex Llc (Active)
- Advisory Reference
- Advisory Reference
Datasheet 6530-01-539-2252
- Characteristic
- Specifications
- FIIG
- Specifications
- T265-D
- Material [MATT]
- Plastic Polyethylene
- Part Name Assigned By Controlling Agency [CXCY]
- Two Lumen Central Venous Catheter With Blue Flextip Arrowg+Ard Bl Catheter 5/Case
- Usage Design [ALCD]
- 1 Two Lumen Indwelling Catheter 7 Fr X 6 5/16 Inch Radiopaque Polyurethane With Blue Flextip Arrowwg+Ard Antimicrobial Surface Treatment Extension Line Clamps, Injection Site Caps; 1 Spring Wire Guide Marked 0.032 Inch Dia 0.032 Inch Dia X 23 5/8 Inch, Straightstiff Tip On One End-J Tip On Other, With Arrow Advancer; 1Catheter 18 Ga X 2.5 Inch Radiopaque Over 20 Ga Rw Introducer Needle; 1 Pressure Catheter Clamp; 1 Pressure Transduction Probe; 1 Iroducer Needle 18 Ga X 2.5 Inch Xtw And 5 Cc Arrow Raulerson Spring Wire Introduction Syringe; 1 Tissue Dilator; 1 Clamp Catheter
NATO Stock Numbers Related to 6530-01-539-2252
Freight Information 6530-01-539-2252
6530-01-539-2252 has freight characteristics managed by Turkey.. 6530-01-539-2252 has a variance between NMFC and UFC when transported by rail and the description should be consulted.