Premium Information is available for this item - Upgrade for $1 a day
6625-01-126-7906
Voltmeter
6625011267906 011267906 611 268512 135-067 891171-1 611-E327
An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. View more Voltmeter
May 2023
21
Marketplace 6625-01-126-7906
Request a Quotation from participating marketplace vendors
Related Documents 6625-01-126-7906 3+ Documents (More...)
Users 6685-15-111-8983 Italy (ZR) Approved Sources 6685-15-111-8983 Part NumberManufacturerStatus1Q 268512
A9840 - Wartsila Italia Spa (Active) Primary Buy RNCC 3 RNVC 2 DAC 1 1Q 268512 A3503 - Diesel Ricerche
Restrictions 6625-01-126-7906
6625-01-126-7906 is a Voltmeter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 6625-01-126-7906
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6625-01-126-7906
- US Navy (N9BN)
- Effective Date:
- 1 Nov 2005
- Former MOE Rule:
- N9ND
- Supplementary Collaborators:
- HD
- Brazil (YA01)
- Effective Date:
- 1 Aug 2010
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Australia (ZA01)
- Effective Date:
- 1 Apr 1991
- France (ZF01)
- Effective Date:
- 1 Apr 1991
- Italy (ZR01)
- Effective Date:
- 1 Jul 1997
- Greece (ZU01)
- Effective Date:
- 1 Aug 2005
Approved Sources 6625-01-126-7906
- Part Number
- Manufacturer
- Status
- 891171-1
- Manufacturer
- 3B150 - Raytheon Company (Active)
- Primary Buy
- Primary Buy
- 611
- 77221 - Phaostron Instrument And Electronic (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 135-067
- 33005 - Jewell Instruments Llc (Active)
- Secondary Buy
- Secondary Buy
- 891171-1
- 54X10 - Raytheon Company (Active)
- Secondary Buy
- Secondary Buy
- 611-E327
- 77221 - Phaostron Instrument And Electronic (Active)
- Secondary Buy
- Secondary Buy
- 891171-1
- 49956 - Raytheon Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 268512
- 65092 - Solartron Electronics Inc (Obsolete)
- Advisory Reference
- Advisory Reference
Datasheet 6625-01-126-7906
- Characteristic
- Specifications
- FIIG
- Specifications
- A310A0
- Accuracy In Percent [APPN]
- -3.0 To 3.0 At Full Scale Single Indicator Single Range
- Background Color [AQFY]
- White Single Indicator Single Range
- Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
- 1.312 Inches Nominal
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 1.312 Inches Nominal
- Circuit Attachment Method And Quantity [CTTD]
- 2 Solder Lug
- Circuit Current For Which Designed [AACT]
- Dc
- Dial Scale Marking Color [APMM]
- Black Single Indicator Single Range
- Dielectric Withstanding Voltage In Volts [AAPB]
- 1500.0
- Furnished Items And Quantity [AKYN]
- Hex Or Square Nut 4,Lock Washer 4
- Environmental Protection [ADZC]
- Shock Resistant And Vibration Resistant
- Features Provided [CBBL]
- Magnetic Shield And Zero Adjuster
- Measurement Range [BHMW]
- -1.5 To 1.5 Volts, Dc Single Indicator Single Range
- Meter Body Diameter Behind Mounting Flange [APSW]
- 1.510 Inches Maximum
- Meter Depth Behind Mounting Flange [APST]
- 1.000 Inches Maximum
- Mounting Arrangement Style [ANRL]
- Four Hole/Stud Rectangular/Square
- Mounting Hole Diameter [ABTB]
- 0.120 Inches Minimum And 0.130 Inches Maximum
- Mounting Facility Type And Quantity [AXHR]
- 4 Unthreaded Hole
- Movement Suspension Method [CTQL]
- Jewel Pivot Base
- Movement Type [AQEC]
- Moving Coil, Permanent Magnet
- Nuclear Hardness Critical Feature [NHCF]
- Nonhardened
- Fsc Application Data [ZZZV]
- Test Set,Electronic Equipment
- Installation Design [AMQY]
- Panel
- Indicator Type [AMKD]
- Dial W/Pointer
- Pointer Color [ASSS]
- Black Single Indicator Single Range
- Power Source [AWZJ]
- External
- Scale Division Quantity [ABWG]
- 10 Single Indicator Single Range
- Scale Graduation Type [BHDC]
- Linear Single Indicator Single Range
- Overall Height [ABKW]
- 1.734 Inches Minimum And 1.766 Inches Maximum
- Overall Length [ABHP]
- 1.625 Inches Maximum
- Overall Width [ABMK]
- 1.734 Inches Minimum And 1.766 Inches Maximum
- Special Features [FEAT]
- Ruggedized
- Style Designator [STYL]
- Rectangular Flush Mtg
- Surface Treatment [SFTT]
- Anodize
DLA Procurement Analysis 6625-01-126-7906
Management Data 6625-01-126-7906
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
NATO Stock Numbers Related to 6625-01-126-7906
Freight Information 6625-01-126-7906
6625-01-126-7906 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 136740. A Sub NMFC of Z. It has a NMFC Description of METERS ELEC/PARTS. 6625-01-126-7906 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 68820 which rates the freight between FCL and LCL. 6625-01-126-7906 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 6625-01-126-7906 is not classified as a special type of cargo when transported by water. 6625-01-126-7906 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6625-01-126-7906
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- MIL-DTL-17667, Neutral Wrapping Paper
- A-A-1051, Paperboard Cushioning
- --
- --
- No special marking
- MIL-DTL-17667, Neutral Wrapping Paper
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
Contracting Technical Data File (CTDF) 6625-01-126-7906 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: