Premium Information is available for this item - Upgrade for $1 a day

6636-00-489-9189

Environmental Testing Chamber

6636004899189 004899189 SLZ9427

A chamber designed exclusively to perform controlled tests under simulated environmental conditions to determine physical changes or damage to items under test due to humidity, immersion, moisture, altitude thermal shock, sand, dust, etc.. View more Environmental Testing Chamber

6636-00-489-9189 CHAMBER,ENVIRONMENTAL TESTING 6636004899189 004899189

Managed by United States
NSN Created on 17 Sep 1969
Data Last Changed
January 2023
NATO Update Count
5
NATO Data Quality
6636-00-489-9189 CHAMBER,ENVIRONMENTAL TESTING 6636004899189 004899189 1/1
NSN 6636-00-489-9189 (Generic Image) 1/1

6636-00-489-9189 Stock and Availability Marketplace 6636-00-489-9189

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
6636-00-489-9189 RQST NE eBay
eBay Updated Every Day
6636-00-489-9189 RQST eBay
Amazon Updated Every Day
6636-00-489-9189 RQST NE Amazon

6636-00-489-9189 Related Documents Related Documents 6636-00-489-9189 5+ Documents (More...)

Documents 6636-01-528-0840 3+ Documents ( More... ) https//www.nsnlookup.com /fsg-66/fsc-6636/us 6636-00-489-9189
Environmental Testing Chamber 6636004899189 -66/fsc-6636 Environmental Chambers and Related Equipment
1972 6636-00-442-0561 Environmental Testing Chamber TMSTRNCC: 3 | RNVC: 2 | DAC: 4 5 Dec 1969 6636-00-489-9189
5 Dec 1969 6636-01-528-0840 Discharge Fixture 3309413-1RNCC: 3 | RNVC: 2 | DAC: 6 2 Mar 2005 6636-00-489-9189
5 Dec 1969 6636-01-528-0840 Discharge Fixture 3309413-1RNCC: 3 | RNVC: 2 | DAC: 6 2 Mar 2005 6636-00-489-9189
6636-01-423-3125 6636014233125 014233125 is a chamber designed exclusively to perform controlled tests under simulated environmental conditions to determine physical changes or damage to items under test due to humidity, immersion, moisture, altitude thermal shock, sand, dust, etc..

6636-00-489-9189 Demil Restrictions 6636-00-489-9189

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: N | PMIC: A | EDC: A | ADPEC: 0

IUID Required

6636-00-489-9189 is a Environmental Testing Chamber that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.

6636-00-489-9189 End Users End Users 6636-00-489-9189

US Air Force (FGG4)
Effective Date:
1 Sep 2000
Former MOE Rule:
FEE4
US Navy (NAGS)
Effective Date:
1 Jun 2005
Former MOE Rule:
NMGS
Supplementary Receivers:
GG
Republic of Korea (ZH01)
Effective Date:
1 Apr 1991

6636-00-489-9189 Manufacturers Approved Sources 6636-00-489-9189

6636-00-489-9189 Technical Data Datasheet 6636-00-489-9189

Characteristic
Specifications
FIIG
T269-E
Special Features [FEAT]
Wind Tunnel

6636-00-489-9189 Management Data Management Data 6636-00-489-9189

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Feb 2020
Department of the Air Force (DF)
EA
Subscribe
1
May 2011
Department of the Navy (DN)
EA
Subscribe
1

Air Force Air Force

Budget:
M
57X3080 - Other Base Maintenance and Support Equipment
Aggregation Code:
RN
GROUND SUPPORT EQUIPMENT (FSC RESIDUAL MMAC)
Price Validation Code:
X
The current standard price has been validated and the previous price was erroneous.
The item was overpriced and the contractor has refunded the overcharge or DoD activities did not actually pay the previous price. The price paid is within the analyzed acceptable range.
If the difference from the previous price exceeds $99.99 or if the price change exceeds 500 percent and the extended value of any affected transaction exceeds $99.99, then reverse-post procedures will apply where the stock fund has overcharged unit O&M Funds. These corrections will be limited to the current fiscal year.
ZOP or Standard Price challenges are permissible but should be supported by adequate justification.
Expendability
Recoverability
Repairability:
S
Reparable. Condemn at Depot. AF Equipment Management System (AFEMS).

Navy Navy

Cognizance:
6R
Bypass
Special Material ID:
XH
SH-60B Electronics Helicopters
Issue, Repair, Requisition Restriction Code:
BS
Submit/refer requisitions to NAVICP PHIL
Special Material Content:
9
Non-Hazardous or Non-Sensitive Item

6636-00-489-9189 Related Items NATO Stock Numbers Related to 6636-00-489-9189

6636-00-489-9189 Freight Data Freight Information 6636-00-489-9189

6636-00-489-9189 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6636-00-489-9189 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6636-00-489-9189 is rated as a variable freight class when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 6636-00-489-9189 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 738 for ocean manifesting and military sealift. 6636-00-489-9189 is not classified as a special type of cargo when transported by water. 6636-00-489-9189 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

6636-00-489-9189 Packaging Data Packaging Data 6636-00-489-9189

Responsible Activity
Packaging Data Source
Secondary Inventory Control Activity (SICA)
Packaging Data does not meet current MIL-STD-2073-1E
Storage Environment
Heated General Purpose – Heated 40 F and above

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
60.0" H x 47.0" W x 47.0" L
--
--
Physical Protection
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
MIL-P-130, Laminated and Creped Wrapping Paper
Wood Blocking and Bracing, Fasteners, or Steel Strapping, for Tie-down purposes. Rubber tired wheels shall be blocked clear of the floor of the crate or skid and shall not be load bearing
Not Applicable
ASTM-D5118, Type CF, Class Weather-Resistant, Corrugated Fiberboard Box
--

Intermediate Pack Level

Quantity of Unit Packs
Container
--
No Requirement